Sign In | Join Free | My himfr.com
Home > PCR Laboratory >

Syphilis PCR Laboratory

    Buy cheap Syphilis PCR Laboratory from wholesalers
     
    Buy cheap Syphilis PCR Laboratory from wholesalers
    • Buy cheap Syphilis PCR Laboratory from wholesalers
    • Buy cheap Syphilis PCR Laboratory from wholesalers

    Syphilis PCR Laboratory

    Ask Lasest Price
    Brand Name : NANBEI
    Certification : CE/ISO
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Delivery Time : 7-10days
    Price : Negotiable
    • Product Details
    • Company Profile

    Syphilis PCR Laboratory

    pcr laboratory setup
    PCR laboratory

    The PCR laboratory is mainly located in the laboratory and pathology department. It can be amplified and analyzed in vitro. To diagnose the prevalence of infectious diseases, cancer, AIDS, hepatitis A, hepatitis B, tuberculosis, syphilis, rubella and other patients. It is usually used for early diagnosis of diseases and various treatment stages. Through the DNA gene tracking system, can quickly grasp the virus content in the patient's body, and its accuracy is as high as nanometers.
    1.Reagent preparation area
    Function: It is mainly used for the preparation of storage reagents, the packaging of reagents and the preparation of the main reaction mixture. The reagents and materials used for specimen preparation should be transported directly to this area, and should not pass through other areas. Reagent raw materials need to be stored in this area, and the required storage reagents are prepared in this area.
    Reagent preparation room: configuration of experimental reagents.
    Reagent configuration steps: Weigh solid medicines with a balance or pipette to take liquid reagents (mix), add ultrapure water to dissolve, can configure electrophoretic solution, sodium acetophenate solution, reagent configuration, can be operated in an ultra-clean workbench.
    CategorySelection Purpose
    BalanceUsed for accurate weighing of various reagents
    Ultra-clean workbenchAll operations involving bacteria must be done under the ultra-clean workbench.
    PipetteAccurately measure a specific volume of solution 20-100ul
    Water purifierUltra pure water 18.2ΩM.CM
    Medicine refrigeratorShort-term storage
    Reagent low temperature refrigeratorOptional 2-8o,-20℃
    MixerNeed to mix before transferring the sample
    Disinfection vehicleSpace environment disinfection
    Sterilization pot

    Sterilization and sterilization of laboratory items, reagents,

    culture media

    PH meterConfiguration reagent is accurate measurement of PH value

    2. Sample preparation area

    Function: preservation of clinical specimens, nucleic acid (RNA, DNA) extraction, storage and DNA synthesis when added to amplification reaction tubes and RNA determination.

    Sample preparation room: nucleic acid extraction and purification

    Extraction: Pipette the sample after mixing, add 0.5% SDS and protease to digest at 70°C (constant temperature water tank), add phenol and chloroform

    CategorySelection Purpose
    Biological safety cabinetTo prevent the spread of harmful suspended particles and aerosols
    Sample RefrigeratorStore samples and DNA in -20°C, -80°C
    High-speed tabletop refrigerated centrifugeIt is used to collect microbial cells, cell debris and other sediments. Some samples require low temperature environment because they are not stable at normal temperature.
    Water bath or metal bathUsed for temperature control of water bath during DNA hybridization
    PipetteAccurately measure a specific volume of solution
    TipsMatching pipettes
    Ultraviolet lamp or disinfection vehicleSpace environment disinfection
    MixerNeed to mix before transferring the sample
    Ultra-clean workbenchAll operations involving bacteria must be done under the ultra-clean workbench.
    Low temperature pressFor shaking culture of E. coli and yeast
    Magnetic stirrerAccelerates the dissolution of solid content

    3. Nucleic acid amplification area

    Function: Mainly DNA amplification, prepared DNA template and synthesized DNA and main reaction mixture, prepared into reaction mixture, etc., can also be carried out in this area. In PCR measurement, the reaction tube is usually opened after amplification.


    CategorySelection purpose
    Gene AmplifierGenetic testing DNA/RNA amplification
    Fluorescence quantitative PCR instrumentNucleic acid quantitative analysis
    Nucleic acid extractorSample DNA/RNA extraction
    PipetteAccurately measure a specific volume of solution
    UV lamp or disinfection vehicleSpace environment disinfection
    Ultra-clean workbenchOperations involving bacteria must be completed under an ultra-clean workbench.
    Water purifier SFor PCR, DNA sequencing requires ultrapure water

    4. Product analysis area


    Function: preservation of clinical specimens, nucleic acid (RNA, DNA) extraction, storage and DNA synthesis when added to amplification reaction tubes and RNA determination.

    Sample preparation room: nucleic acid extraction and purification

    Extraction: Pipette and mix the sample, add 0.5% SDS and protease to digest at 70°C (constant temperature water tank), add benzene and chloroform

    CategorySelection purpose
    ElectrophoresisHorizontal electrophoresis is used for nucleic acid DNA/RNA detection, vertical electrophoresis is used for protein detection, and transfer electrophoresis is used to transfer protein to the membrane for western detection.
    Gel imaging system/UV detectorFor nucleic acid agar electrophoresis and protein polyacrylamide observation and photographing; UV analyzer is used for nucleic acid agar electrophoresis gel observation after staining, can not be connected to a computer
    Electric stoveElectrophoresis agar gel melted by heating

    Quality Syphilis PCR Laboratory for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: NANBEI INSTRUMENT LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)